Compatibility of Refrigerants and Lubricants with Motor Materials Under Retrofit Conditions. Final Report, Volume IV - Pictures
Download or Read eBook Compatibility of Refrigerants and Lubricants with Motor Materials Under Retrofit Conditions. Final Report, Volume IV - Pictures PDF written by and published by . This book was released on 1996 with total page 45 pages. Available in PDF, EPUB and Kindle.
Author | : |
Publisher | : |
Total Pages | : 45 |
Release | : 1996 |
ISBN-10 | : OCLC:68410872 |
ISBN-13 | : |
Rating | : 4/5 (72 Downloads) |
Book Synopsis Compatibility of Refrigerants and Lubricants with Motor Materials Under Retrofit Conditions. Final Report, Volume IV - Pictures by :
Book excerpt: Compatibility tests were conducted on motor materials to determine if exposure to the original refrigerant/mineral oil would affect compatibility of the motor materials after retrofit to the alternative refrigerant/lubricant. The motor materials were exposed at elevated temperature to the original refrigerant and mineral oil for 500 hours, followed by exposure to the alternative refrigerant and lubricant for 500 hours. Measurements were also taken after 168 and 336 hours. As a control, some samples were exposed to the original refrigerant/mineral oil for a total of 1000 hours.